Send Message

Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath

500 m
MOQ
On Request
Price
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath
Features Gallery Product Description Request A Quote
Features
Specifications
Nominal Voltage: 12/20 KV
Insulation: XLPE
No. Of Conductor: Single & 3 Core
Sheath: PVC Compound
Conductor Material: Bare Copper Class 2
Manufacturer: Shenzhen Chengtiantai
High Light:

xlpe power cable

,

medium voltage underground cable

Basic Infomation
Place of Origin: Shenzhen, China (mainland)
Brand Name: Chengtiantai
Certification: CE, ISO, IEC
Payment & Shipping Terms
Packaging Details: Iron wooden drum or as required
Delivery Time: 7/15 working days
Payment Terms: L/C, T/T
Supply Ability: 18,000 m per month
Product Description

12/ 20 kV Copper conductor XLPE ( Cross-linked Polyethylene )  Insulated PVC Sheathed cable

 

stranded copper conductor - conductor screen of semiconducting compound - XLPE insulation - core screen of semiconducting compound - copper tape screen - separation tape - PVC sheath

 

suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground as well as for installation on cable trays for industries, switchboards and power stations.

 

Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 0

  STANDER

International:IEC60502-2

National:GB/T 12706.1-2008

  CONSTRUCTION:

1. CONDUCTOR

– Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

2. CONDUCTOR SCREEN

– Inner semi-conducting coating

3. INSULATION

– Core insulation of cross-linked polyethylene (XLPE)

4. INSULATION SCREEN

– Outer conductive layer extruded and per-manently welded with the core insulation

Semi-conducting type
– Over the outer semi-conducting layer, a semiconducting tape must be used.

5. METAL SCREEN

– copper tapes helically with a minimum thickness of 0,1 mm.

Separator
– Over the screen as well as under outer sheath, a separating layer must be used (e. g. taping).

6. SHEATH

– Outer sheath of PVC compound

  CHARACTERISTICS

 

Construction characteristics

Conductor shape Circular stranded (RM)
Lead free Yes
Insulation XLPE
Screen copper tape
Material of bedding Separation tape
Outer sheath  PVC
Usage characteristics
Packaging Steel Wooden Drum
Minimum installation temperature  -20 °C
Max. conductor temperature in service  90 °C
Short-circuit max. conductor temperature  250 °C
Bending factor when laying  20 (xD)

 

  1 CORE CABLE PHYSICAL AND ELECTRICAL CHARACTERISTICS :

No. of cores and cross -sec. Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² kV kV mm mm mm kg / km A A Ω/km
1 x 35 24 12/ 20 5.5 1.8 24.9 860 205 190 0.52
1 x 50 24 12/ 20 5.5 1.8 26.4 1138 245 225 0.39
1 x 70 24 12/ 20 5.5 1.9 28.1 1281 305 275 0.27
1 x 95 24 12/ 20 5.5 1.9 29.9 1570 370 330 0.19
1 x 120 24 12/ 20 5.5 2.0 31.3 1839 430 375 0.15
1 x 150 24 12/ 20 5.5 2.0 33.1 2174 490 425 0.12
1 x 185 24 12/ 20 5.5 2.1 34.7 2540 560 480 0.10
1 x 240 24 12/ 20 5.5 2.2 37.1 3120 665 555 0.08
1 x 300 24 12/ 20 5.5 2.2 39.5 3746 765 630 0.06
1 x 400 24 12/ 20 5.5 2.3 44.1 4863 890 725 0.05
1 x 500 24 12/ 20 5.5 2.4 47.6 5905 1030 825 0.04
1 x 630 24 12/ 20 5.5 2.5 51.3 7220 1190 940 0.03


  3 CORES CABLE PHYSICAL AND ELECTRICAL CHARACTERISTICS :

 

No.cores x
cross-sec.

Operation
voltage
max.

Nominal
voltage
U0/U

Insulation
thickness

Sheath
thickness
Nominal
value

Outer Ø
approx.

weight
approx.

Current ratings in air 30

Current ratings buried 20

maximum DC resistance at 20

mm² kV kV mm mm mm kg / km A A Ω/km
3 x 35 24 12/20 5.5 2.6 52.5 3023 155 185 0.52
3 x 50 24 12/20 5.5 2.7 55.5 3891 180 218 0.39
3 x 70 24 12/20 5.5 2.8 59.3 4396 223 267 0.27
3 x 95 24 12/20 5.5 3.0 63 5264 271 318 0.19
3 x 120 24 12/20 5.5 3.1 66.2 6190 312 363 0.15
3 x 150 24 12/20 5.5 3.2 69.8 7240 363 417 0.12
3 x 185 24 12/20 5.5 3.3 73.7 8499 404 460 0.1
3 x 240 24 12/20 5.5 3.5 78.6 10353 471 531 0.08
3 x 300 24 12/20 5.5 3.6 83.8 12328 536 596 0.06
3 x 400 24 12/20 5.5 3.8 93.6 15921 630 684 0.05

*Core identification: colored tapes under screen.

 

*Dimensions and specifications may be changed without prior notice.

 

  MEDIUM VOLTAGE CABLE TESTING

 

Routine tests: Sample tests: Type tests:
These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath
These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test
These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
- Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

 

  PACKING AND SHIPPING

 

Packing: steel wooden drum, other as required ; standard delivery length is 300 m

 

Packaging details :

Delivery :

Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 1 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 2

Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 3

Steel Wooden Drums Cable Drum In container  shipped in 15 days after payment

 

  Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 4 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

 

 

  Delivery Port:

 

Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 5 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 6 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 7
Port of Shenzhen  Port of Hongkong  Port of Guangzhou

 

  Our production in numbers

 

Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 8

● Cable production started 1983
35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

100,000 m2 Production area
350 Will-trained employees
● Exported more than 22 countries
2 Manufacturing plant
1 R&D Center

200 Sets Of Testing Equipment

100 Testing Items
8 workshop
40 wire drawing machines
10 bunching machines
28 Extruder system
42 stranding machines
10 Braiding machines

 
  Shenzhen chengtiantai cable operates certified management systems compliant with:
 
  Certificat Information
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 9
ISO 9001:2008
Quality management systems

 

Certificat ISO 9001:2008
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 10
ISO 14001:2004
Environmental management systems

Certificat ISO 14001:2004

- Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 11
OHSAS 18001:2007
Assessment specification for occupational health & safety management systemsenvironmental management systems
Certificat OHSAS 18001:2007
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

 

  Manufacturing Process Of Medium Voltage Power Cable

 

Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 12 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 13 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 14
1. copper rod 2. wire drawing 3. wire stranding
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 15 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 16 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 17
4.Triple Extrusion Insulation 5.Screening Process 6. outer covering Process
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 18 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 19 Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 20
7. Sheath Marking 8. Packing 9. Partial discharge Inspection

 

  Some great shot on our manufacturing plant

 

Located in: Chengtiantai Industrial Park, Guangming New District, Shen zhen P. R. China 518106
 
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 21Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 22Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 23Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 24
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 25Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 26Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 27
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 28
 

  Customer services:

 
Triplex / Single Core Medium Voltage Power Cables 12/ 20 KV PVC Compound Sheath 29

  RECOMMENDED ORDERING PARAMETERS

  CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

  WARRANTY

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Recommended Products
Get in touch with us
Contact Person : Annie Chen
Tel : +8613670012325
Fax : 86-755-29886488
Characters Remaining(20/3000)