Features
Specifications
Rated Voltage: 0,6 / 1 KV
Conductor: Bear Copper
No. Of Conductor: From 1 To 5 Cores
Insulation 1st Layer: Mica Tape
Insulation 2nd Layer: XLPE
Sheath: LSZH
High Light:

electrical power cable

,

xlpe pvc cable

Basic Infomation
Place of Origin: Shenzhen City, Mainland China
Brand Name: Chengtiantai cable
Certification: CE, CB
Model Number: NH-YJV
Payment & Shipping Terms
Packaging Details: Steel wooden Drum
Delivery Time: 15 working days after payments
Payment Terms: L/C, T/T
Supply Ability: 10000 m / day
Product Description

 

Fire Resistant Cables XLPE Insulated 0.6/1 kV

 

APPLICATIONS:


Essential safety circuits associated with fire fighting equipment,emergency lighting and particulary for power supplies to build equipment used in safety systems. With special fire performance such as fire retardancy, halogen free and low emission of smoke and fumes.

 

CONSTRUCTION:

1. CONDUCTOR

Copper class 1 up to 6 mm2 and class 2

for sections above to IEC 60228.

2. INSULATION (first layer)

Mineral ceramic fire resistant tape (Mica).

3. INSULATION (second layer)

Cross-linked polyethylene type XLPE to IEC 60502-1.

Identification by colour.

4. CORE WRAPPING

Core wrapping with glass-fibre tape as flame-protection

5. SHEATH

Halogen-free thermoplastic polyolefin, type ST8 to IEC 60502-1.

6. SHEATH COLOR

Orange or black

Maximum temperature rating of the conductor: +90 °C
Minimum working temperature: -40 °C

Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 0

 

  Physical and Electrical Characteristics:

 

Single Core

 

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
1×1.5 0.7 1.4 5.8 45 32 43 12.1
1×2.5 0.7 1.4 6.2 57 42 57 7.41
1×4.0 0.7 1.4 6.7 75 56 74 4.61
1×6.0 0.7 1.4 7.2 97 70 93 3.08
1×10 0.7 1.4 8.2 142 97 127 1.83
1×16 0.7 1.4 9.2 205 125 167 1.15
1×25 0.9 1.4 10.8 304 165 216 0.73
1×35 0.9 1.4 11.8 403 200 261 0.52
1×50 1.0 1.4 13.3 555 245 311 0.39
1×70 1.1 1.4 15.3 756 305 388 0.27
1×95 1.1 1.5 17.1 1005 375 461 0.19
1×120 1.2 1.5 18.7 1250 435 527 0.15
1×150 1.4 1.6 20.9 1561 500 592 0.12
1×185 1.6 1.6 22.9 1910 580 671 0.10
1×240 1.7 1.7 25.5 2453 685 781 0.08
1×300 1.8 1.8 28.2 3044 795 886 0.06
1×400 2.0 1.9 32.0 4024 930 1019 0.05
1×500 2.2 2.0 35.4 5006 1080 1170 0.04

 

 

2 Cores

 

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
2×2.5 0.7 1.8 10.6 140 37 54 7.41
2×4.0 0.7 1.8 11.6 192 47 70 4.61
2×6.0 0.7 1.8 12.6 245 60 86 3.08
2×10 0.7 1.8 15.2 362 84 115 1.83
2×16 0.7 1.8 16.6 514 113 149 1.15
2×25 0.9 1.8 19.8 734 150 191 0.73
2×35 0.9 1.8 17.2 968 185 231 0.52
2×50 1.0 1.8 19.4 1190 226 275 0.39
2×70 1.1 1.9 22.0 1591 287 337 0.27
2×95 1.1 2.0 24.6 2117 354 405 0.19
2×120 1.2 2.1 27.4 2617 431 463 0.15
2×150 1.4 2.2 30.2 3239 494 522 0.12
2×185 1.6 2.3 34.0 5126 592 591 0.10

 

3 Cores

 

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
3×1.5 0.7 1.8 10.1 132 21 28 12.1
3×2.5 0.7 1.8 11.0 171 28 37 7.41
3×4.0 0.7 1.8 12.0 225 37 48 4.61
3×6.0 0.7 1.8 13.1 296 47 61 3.08
3×10 0.7 1.8 15.3 440 64 82 1.83
3×16 0.7 1.8 17.5 638 85 107 1.15
3×25 0.9 1.8 21.0 954 115 138 0.73
3×35 0.9 1.8 23.1 1266 140 165 0.52
3×50 1.0 1.8 23.4 1614 168 198 0.39
3×70 1.1 1.9 27.4 2264 213 242 0.27
3×95 1.1 2.0 30.6 2975 263 290 0.19
3×120 1.2 2.1 34.0 3776 307 330 0.15
3×150 1.4 2.3 38.6 4682 357 371 0.12
3×185 1.6 2.4 43.3 5802 415 418 0.10
3×240 1.7 2.6 48.1 7437 498 485 0.08
3×300 1.8 2.8 52.2 9313 575 548 0.06

 

4 Cores

 

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
4×4 0.7 1.8 13.0 283 38 50 4.61
4×6 0.7 1.8 14.2 376 49 62 3.08
4×10 0.7 1.8 16.7 567 67 84 1.83
4×16 0.7 1.8 19.1 829 88 109 1.15
4×25 0.9 1.8 23.2 1249 119 142 0.73
4×35 0.9 1.8 25.2 1689 146 170 0.52
4×50 1.0 1.9 25.5 2146 173 201 0.39
4×70 1.1 2.0 28.9 2944 218 245 0.27
4×95 1.1 2.1 32.5 3903 271 294 0.19
4×120 1.2 2.3 35.9 4967 315 333 0.15
4×150 1.4 2.4 40.2 6133 366 374 0.12
4×185 1.6 2.6 44.4 7600 422 421 0.10
4×240 1.7 2.8 49.4 9743 508 489 0.08
4×300 1.8 3.0 56.0 12271 592 555 0.06

 

3 Core+ Earth
 

No.cores x

cross-sec.

Insulation

thickness

Nominal

Sheath

thickness

Outer Ø

approx.

weight

approx.

Current ratings in air 30℃ Current ratings buried 20℃
Phase Neutral
mm² mm mm mm mm kg / km A A
3×4+1×2.5 0.7 0.7 1.8 12.7 277 37 47
3×6+1×4.0 0.7 0.7 1.8 13.9 363 47 60
3×10+1×6.0 0.7 0.7 1.8 16.1 527 64 81
3×16+1×10 0.7 0.7 1.8 18.6 766 85 106
3×25+1×16 0.9 0.7 1.8 22.2 1140 113 137
3×35+1×16 0.9 0.7 1.8 24.6 1475 139 164
3×50+1×25 1.0 0.9 1.8 27.7 1951 173 198
3×70+1×35 1.1 0.9 1.9 31.9 2662 222 246
3×95+1×50 1.1 1.0 2.1 36.2 3578 271 293
3×120+1×70 1.2 1.1 2.2 39.9 4567 318 334
3×150+1×70 1.4 1.1 2.3 45.0 5514 370 375
3×185+1×95 1.6 1.1 2.5 49.4 6850 427 422
3×240+1×120 1.7 1.2 2.7 54.9 8741 507 492
3×300+1×150 1.8 1.4 2.9 62.9 11052 599 560
 

5 Cores

 

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
5×4 0.7 1.8 14.7 320 38 48 4.61
5×6 0.7 1.8 15.8 427 48 60 3.08
5×10 0.7 1.8 18.6 636 66 81 1.83
5×16 0.7 1.8 21.3 941 88 107 1.15
5×25 0.9 1.8 25.7 1441 118 137 0.73
5×35 0.9 1.8 28.4 1853 144 165 0.52
5×50 1.0 2.0 32.9 2616 177 196 0.39
5×70 1.1 2.1 38.2 3578 227 244 0.27
5×95 1.1 2.3 43.4 4843 277 288 0.19
5×120 1.2 2.4 47.9 6110 325 329 0.15
5×150 1.4 2.6 53.8 7421 375 369 0.12
5×185 1.6 2.8 59.6 9191 433 418 0.10
5×240 1.7 3.0 66.5 11763 518 488 0.08
5×300 1.8 3.2 73.4 14595 625 555 0.06

 

4 Core+Earth
 

No.cores x

cross-sec.

Insulation

thickness

Nominal

Sheath

thickness

Outer Ø

approx.

weight

approx.

Current ratings in air 30℃ Current ratings buried 20℃
Phase Neutral
mm² mm mm mm mm kg / km A A
4×4+1×2.5 0.7 0.7 1.8 14.2 320 38 48
4×6+1×4.0 0.7 0.7 1.8 15.6 427 48 60
4×10+1×6.0 0.7 0.7 1.8 18.1 636 66 81
4×16+1×10 0.7 0.7 1.8 20.8 941 88 107
4×25+1×16 0.9 0.7 1.8 24.9 1441 118 137
4×35+1×16 0.9 0.7 1.8 27.1 1853 144 165
4×50+1×25 1.0 0.9 1.9 31.6 2616 177 196
4×70+1×35 1.1 0.9 2.1 36.5 3578 227 244
4×95+1×50 1.1 1.0 2.2 41.6 4843 277 288
4×120+1×70 1.2 1.1 2.4 46.3 6110 325 329
4×150+1×70 1.4 1.1 2.5 51.2 7421 375 369
4×185+1×95 1.6 1.1 2.7 56.8 9191 433 418
4×240+1×120 1.7 1.2 2.9 63.2 11763 518 488
4×300+1×150 1.8 1.4 3.1 70.0 14595 625 555
 
*Dimensions and specifications may be changed without prior notice.
 

Conductor Design

 
Low Voltage Power Cable 0.6/1 kV XLPE Insulated Cables

 

  Packaging & Delivery

 
Packaging details :
Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 2 Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 3 Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 4
100 m/ coil in foil Steel Wooden Drums Cable Drum In container 

 

Delivery : shipped in 15 days after payment

  Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 5 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

 

 

  Delivery Port:

 

Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 6 Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 7 Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 8
Port of Shenzhen  Port of Hongkong  Port of Guangzhou

 

 
  Shenzhen chengtiantai cable operates certified management systems compliant with:
 
  Certificat Information
Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 9

 

ISO 9001:2008

quality management systems

Certificat ISO 9001:2008
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 13 January 2019

Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 10

ISO 14001:2004

environmental management systems

Certificat ISO 14001:2004

- Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

Fire Resistant Cables 0.6/1 kV Copper conductor XLPE Insulated LSZH Sheathed 11

OHSAS 18001:2007

assessment specification for occupational health & safety management systemsenvironmental management systems

Certificat OHSAS 18001:2007

- Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 13 January 2019

 
CUSTOMER SERVICES: Single Core PVC Wiring Cable

We manufactures a comprehensive array of wires and cables to meet diverse market needs.

 

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028

Fax:+86 755 61137976

E-mail : cttcable@hotmail.com

Shenzhen chengtiantai cable operates certified management systems compliant with: ISO 9001:2008 / ISO 14001:200]4 / OHSAS 18001:2007

 

● Cable production started 1983
● 35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

● 100,000 m2 Production area
● 350 Will-trained employees

● 8 workshop
● 1 R&D Center

 

Head office: chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

Because we continuously improve our products, CTT Cable reserves the right to change specifications and availability without prior notice.

Recommended Products
Get in touch with us
Contact Person : Annie Chen
Tel : +8613670012325
Fax : 86-755-29886488
Characters Remaining(20/3000)